Free Newsletter
Register for our Free Newsletters
Newsletter
Zones
Analysis, Inspection and Laboratory
LeftNav
Assisted/Independent Living
LeftNav
Clinical and Nursing Equipment
LeftNav
Design and Manufacture of Medical Equipment
LeftNav
Diagnostics Equipment, Monitoring and Test
LeftNav
Education, Training and Professional Services
LeftNav
Health Education and Patient Management
LeftNav
Health Estates Management
LeftNav
Healthcare Support and Information Services
LeftNav
Hygiene and Infection Control
LeftNav
IT and Communications in Healthcare
LeftNav
Materials
LeftNav
Medical Device Technology
LeftNav
Research and Development
LeftNav
Safety and Security
LeftNav
View All
Other Carouselweb publications
Carousel Web
Defense File
New Materials
Pro Health Zone
Pro Health Zone
Pro Security Zone
Web Lec
Pro Engineering Zone
 
 
News

Bioimpedance measurement lowers image degradation of PET scans, improves detection of cancer and heart conditions

University Of Eastern Finland : 26 October, 2014  (Technical Article)
A novel technique which reduces image degradation caused by respiratory motion during a PET scan was developed in a recent study at the University of Eastern Finland.
Bioimpedance measurement lowers image degradation of PET scans, improves detection of cancer and heart conditions

PET scanning is routinely used to detect cancer and heart conditions. It is used for cancer staging and evaluating treatment response, as well as for studying myocardial blood flow and inflammatory diseases of the heart. Typically, a PET scan takes several minutes, which is why movement caused by the patient's breathing inevitably degrades image quality. Degraded image quality caused by respiratory motion has been reported to affect PET scanning performed to detect cancer and heart conditions in particular. At worst, image degradation may lead to a wrong diagnosis and inadequate or unnecessary treatment.


 


Now, a new technique presented in the PhD thesis of Tuomas Koivumäki, MSc (Tech.), is based on bioimpedance measurement and it allows for image reconstruction at a specific phase of the patient's breathing pattern. This, in turn, makes it possible to reduce image degradation caused by motion.


 


In the future, the newly developed technique will enable increasingly accurate image acquisition especially during PET scans performed to detect cancers of the chest and upper abdomen, and inflammatory diseases of the heart. PET scanning, or positron emission tomography, is a modern nuclear medicine imaging method, which allows for the detection of cancer and heart conditions.


 


Thanks to enhanced image quality, PET images provide new and increasingly accurate data, potentially improving diagnosis reliability and treatment response monitoring. High-quality image data makes the treatment more efficient both medically and financially.


 


The study found that when synchronising images on the basis of bioimpedance, it was possible to discern smaller details. Motion compensation also significantly influenced the parameters measured from the images. Bioimpedance measurement offers a straightforward technique for acquiring the data needed for motion compensation. Furthermore, the technique can be easily integrated into electrocardiogram (ECG) measurement, which is widely used to monitor heart function during the scan.


 


In techniques based on bioimpedance measurement, a very weak electrical current is passed through the patient's chest, and changes in the resulting voltage are measured. The voltage has been observed to change according to the patient's breathing and cardiac function. Earlier, bioimpedance measurements have been used to assess for example body composition, fluid accumulations in lungs, and indicators of cardiac function.


 


The study focused on the feasibility of bioimpedance-based measurement techniques for respiratory and cardiac motion compensation in PET imaging. The study first used computational models and test subjects to determine an optimised bioimpedance measurement configuration for simultaneous measurement of respiratory and cardiac gating signals. The second phase of the study focused on analysing whether bioimpedance techniques can be used to reduce respiration-related degradation of PET images.


 



Right: Schematic image of the thorax with lung and liver lesions without (A) and with (B) motion. Lesions (black) are evidently blurred in B, and the visibility of the small liver lesion is compromised. The figure is created using image processing and is based on arbitrary motion.


 



 


 



 