Free Newsletter
Register for our Free Newsletters
Newsletter
Zones
Analysis, Inspection and Laboratory
LeftNav
Assisted/Independent Living
LeftNav
Clinical and Nursing Equipment
LeftNav
Design and Manufacture of Medical Equipment
LeftNav
Diagnostics Equipment, Monitoring and Test
LeftNav
Education, Training and Professional Services
LeftNav
Health Education and Patient Management
LeftNav
Health Estates Management
LeftNav
Healthcare Support and Information Services
LeftNav
Hygiene and Infection Control
LeftNav
IT and Communications in Healthcare
LeftNav
Materials
LeftNav
Medical Device Technology
LeftNav
Research and Development
LeftNav
Safety and Security
LeftNav
View All
Other Carouselweb publications
Carousel Web
Defense File
New Materials
Pro Health Zone
Pro Health Zone
Pro Security Zone
Web Lec
Pro Engineering Zone
 
 
News

Medtronic reveals Endeavor Resolute DES two-year trial data

Medtronic : 13 October, 2008  (Company News)
Of patients treated with the Endeavor Resolute drug-eluting stent (DES) from Medtronic in the RESOLUTE IDE trial only two required repeat procedures a 1.5 percent rate of target lesion revascularization (TLR) at two years following implant, according to data released at the Transcatheter Cardiovascular Therapeutics (TCT) symposium in Washington, DC, USA.
There were no instances of Stent thrombosis among the 130 study subjects all of whom received an Endeavor Resolute DES through 24 months of follow-up.

“The goal of the RESOLUTE clinical programme is to extend the proven long-term safety and durable efficacy benefits that our flagship Endeavor DES offers to patients who are underserved by currently available treatment alternatives,” said Sean Salmon, vice president and general manager of the Coronary and Peripheral Vascular business at Medtronic. “The Resolute DES will complement our coronary Stent portfolio as we seek to address the unmet clinical needs of patients at high risk of restenosis.”

The patients enrolled in RESOLUTE represented an unusually high degree of complexity for an initial clinical trial of a new DES. Average lesion length was 15.5 mm, and 82 percent of the subjects had challenging B2/C lesions. In addition, 46 percent had a prior myocardial infarction (MI), and 18 percent had a prior percutaneous coronary intervention (PCI); 18 percent had diabetes; 30 percent had unstable angina; and 22 percent were smokers at the time of enrollment.

“Based on the TLR and Stent thrombosis rates of most other drug-eluting stents, the performance of Endeavor Resolute in this trial is encouraging,” said prof Ian Meredith of Monash Medical Centre in Australia and principal investigator of RESOLUTE. “That’s a credit to the noninflammatory properties of the drug zotarolimus and the BioLinx polymer’s biocompatibility and elution profile. The clinical and angiographic results are all the more impressive when you consider the complexity and challenging characteristics of the patients in the study.”

Medtronic’s portfolio of coronary stents provides physicians with choices to address the spectrum of clinical needs. The international portfolio includes the Endeavor and Endeavor Resolute drug-eluting stents and the Driver and Micro-Driver bare-metal stents. All of Medtronic’s coronary stents share the same cobalt alloy platform, which features a modular architecture that provides radial strength but with high conformability to the vessel wall. Both of the company’s drug-eluting stents use the potent antiproliferative, noncytotoxic drug zotarolimus.

Medtronic’s two drug-eluting stents also use highly biocompatible polymers. The Endeavor Resolute DES uses the proprietary BioLinx polymer, which was designed to meet the same biocompatibility requirements as the phosphorylcholine (PC) polymer used in the Endeavor DES. Compared to the PC polymer, the BioLinx polymer is designed to extend the duration of drug exposure in the vessel an elution profile of potential relevance to patients that physicians consider to be at highest risk of needing a repeat procedure. Developed by Medtronic scientists, it is the first polymer created specifically for use on a DES.