Free Newsletter
Register for our Free Newsletters
Newsletter
Zones
Analysis, Inspection and Laboratory
LeftNav
Assisted/Independent Living
LeftNav
Clinical and Nursing Equipment
LeftNav
Design and Manufacture of Medical Equipment
LeftNav
Diagnostics Equipment, Monitoring and Test
LeftNav
Education, Training and Professional Services
LeftNav
Health Education and Patient Management
LeftNav
Health Estates Management
LeftNav
Healthcare Support and Information Services
LeftNav
Hygiene and Infection Control
LeftNav
IT and Communications in Healthcare
LeftNav
Materials
LeftNav
Medical Device Technology
LeftNav
Research and Development
LeftNav
Safety and Security
LeftNav
View All
Other Carouselweb publications
Carousel Web
Defense File
New Materials
Pro Health Zone
Pro Health Zone
Pro Security Zone
Web Lec
Pro Engineering Zone
 
 
News

New Carl Zeiss system handles fluorescence applications under live cell conditions

Carl Zeiss MicroImaging : 06 August, 2008  (New Product)
The Definite Focus module from Carl Zeiss offers a system for the Axio Observer.Z1 that can be used not only for the research of cell cultures in many biomedical applications such as cell biology, pharmacology, molecular genetics, developmental biology and the neurosciences, but also in basic research.
The system has been specially designed for fluorescence applications and time-lapse experiments under live cell conditions. Definite Focus effectively counteracts drifting in the Z-direction. The microscopic image always remains in focus. Furthermore, preparation and waiting times in time-lapse experiments are markedly reduced.

Definite Focus is coupled directly to the nosepiece carrier and directs infrared light of wavelength 835 nm into the beam path of the Axio Observer.Z1 inverted research microscope. To measure the distance between the objective and the specimen, a grid is projected onto the bottom of the culture vessel, and the reflection of this projection is analysed. Possible deviations from the nominal value are determined and corrected quickly and very precisely via the Z-drive of the Axio Observer in the case of drifting. Even with high-magnification objectives, the system can be used without limitations for all contrasting techniques.

Definite Focus offers increased experimental reliability. Experiments that can no longer be evaluated due to drifting in the Z-direction are a thing of the past. Furthermore, incubation conditions can now be better structured according to needs. With stage incubation using the PM S1 incubator, for example, the user can quickly change the temperature as required during the experiment. Typical examples of dynamic temperature experiments include the analysis of protein folding mutants or heatshock experiments. Until now, performance of the relevant experiments had not been possible due to pronounced focus fluctuations.

Definite Focus can be operated directly via the TFT touchscreen display of Axio Observer.Z1. Convenient additional functions such as the storage of two nominal values and the possibility of using the system as a ‘focus finder’ after replacement of the culture vessel are integrated into the system. Furthermore, Definite Focus is fully compatible with the AxioVision and LSM software from Carl Zeiss. The module supports all Axio Observer options such as TIRF, LSM or multiphoton microscopy. The module works with all standard culture vessels, including multiwell dishes with glass or plastic bottoms. The supplied hardware comprises a sensor module on the nosepiece carrier, a beam combiner below the nosepiece and a Definite Focus controller.
Bookmark and Share
 
Home I Editor's Blog I News by Zone I News by Date I News by Category I Special Reports I Directory I Events I Advertise I Submit Your News I About Us I Guides
 
   Â© 2012 ProHealthServiceZone.com
Netgains Logo