Free Newsletter
Register for our Free Newsletters
Newsletter
Zones
Analysis, Inspection and Laboratory
LeftNav
Assisted/Independent Living
LeftNav
Clinical and Nursing Equipment
LeftNav
Design and Manufacture of Medical Equipment
LeftNav
Diagnostics Equipment, Monitoring and Test
LeftNav
Education, Training and Professional Services
LeftNav
Health Education and Patient Management
LeftNav
Health Estates Management
LeftNav
Healthcare Support and Information Services
LeftNav
Hygiene and Infection Control
LeftNav
IT and Communications in Healthcare
LeftNav
Materials
LeftNav
Medical Device Technology
LeftNav
Research and Development
LeftNav
Safety and Security
LeftNav
View All
Other Carouselweb publications
Carousel Web
Defense File
New Materials
Pro Health Zone
Pro Health Zone
Pro Security Zone
Web Lec
Pro Engineering Zone
 
 
News

New self-expanding intracoronary prosthesis limits arterial injuries from stents

Prescient Medical : 30 May, 2008  (Company News)
Three patients with established cardiac ischemia have become the first recipients of Prescient Medical’s vProtect Luminal Shield, a self-expanding intracoronary prosthesis designed to limit arterial injury that typically occurs when stents are deployed.
The Shield also provides robust biocompatible support for the vessel to ensure that the target coronary artery will remain patent after placement.

The patients were treated May 8 to 9 2008 by Juan F Granada, MD (Cardiovascular Research Foundation, New York, USA) and Juan A Delgado, MD (Corbic Institute-MUA) at the Corbic Institute-MUA in Envigado, Colombia. The target lesions ranged from 60 to 80 percent stenosis before the vProtect Luminal Shields were deployed.

In the first patient, a 75 percent occlusion in the mid-circumflex coronary artery underwent pre-dilatation at low pressure with a 2.5 x 9mm balloon and then received a 3.5 x 1 mm luminal shield. After gentle post-dilatation, angiography revealed that blood flow had been restored to the distal portion of the treated vessel.

In the second patient, an 80 percent occlusion in the middle of the left anterior descending (LAD) branch required pre-dilatation with a 2.5 x 9mm balloon. Additional lumen gain was achieved by Shield placement and post-dilatation, again achieving restoration of blood flow distal to the treated segment.

The third patient was a challenging case with a 65 percent occlusion in the mid-LAD, located in a bend near a side branch ostium. The vProtect Luminal Shield was chosen for this patient based on its mechanical properties, including high vascular conformability. Because of its flexibility, the vProtect Luminal Shield was able to access the tortuous anatomy and cross the lesion successfully. Restoration of flow was achieved without angiographic evidence of straightening of the target vessel, a common occurrence with rigid balloon-expandable stents. In addition, the side branch was preserved without evidence of plaque shifting or worsening stenosis.

'The vProtect Luminal Shield and delivery system performed extremely well,' according to Dr Granada. 'The three patients we treated presented with lesions representative of what we see in daily clinical practice and we were able to cross these lesions and deliver the device safely in each case. Although the vProtect Luminal Shield has ultra-thin struts to promote healing, it maintains an intrinsic radial force that matches the vessel compliance. I am very pleased with these early results'.