Free Newsletter
Register for our Free Newsletters
Newsletter
Zones
Analysis, Inspection and Laboratory
LeftNav
Assisted/Independent Living
LeftNav
Clinical and Nursing Equipment
LeftNav
Design and Manufacture of Medical Equipment
LeftNav
Diagnostics Equipment, Monitoring and Test
LeftNav
Education, Training and Professional Services
LeftNav
Health Education and Patient Management
LeftNav
Health Estates Management
LeftNav
Healthcare Support and Information Services
LeftNav
Hygiene and Infection Control
LeftNav
IT and Communications in Healthcare
LeftNav
Materials
LeftNav
Medical Device Technology
LeftNav
Research and Development
LeftNav
Safety and Security
LeftNav
View All
Other Carouselweb publications
Carousel Web
Defense File
New Materials
Pro Health Zone
Pro Health Zone
Pro Security Zone
Web Lec
Pro Engineering Zone
 
 
News

New study shows DSCT enables dosages to be reduced for heart exams

Siemens Healthcare Deutschland : 17 July, 2008  (Company News)
A new study at the University Hospital in Zurich in Switzerland has revealed that, with dual-source computed tomography (DSCT), the effective dosage for a heart examination can be significantly lowered, compared with conventional computed tomography (CT).
The study also demonstrated that stenoses can be diagnosed with the same high accuracy as with invasive X-ray angiography. At the University Hospital in Zurich in Switzerland, 120 patients with suspected coronary heart disease were scanned with the world's first CT scanner with two X-ray tubes; a Somatom Definition from Siemens Healthcare.

The Siemens application, Adaptive Cardio Sequence with the step-and-shoot mode, was also used for the first time with a dual-source CT. The results of the study were published in the June issue of Heart, the official journal of the British Cardiovascular Society (Ref 1).

Angiography is a diagnostic procedure used to clarify coronary arterial occlusion. Normally, this examination is conducted using angiography devices in the Catheter laboratory and computed tomographs (CT), but with CT, the question of the radiation dosage plays a huge role.

Researchers at the University Hospital in Zurich now want to see whether the dose used during CT angiography can be reduced. The research team examined 120 patients with suspected coronary heart disease in a Somatom Definition from Siemens, the world's first computed tomograph with two X-ray tubes.

The researchers used the new application ĎAdaptive Cardio Sequence’, which was recently developed by Siemens for all Somatom Definition Scanners. The application is based on the step-and-shoot method, in which the next respective diastole is calculated and only this phase of the cardiac cycle is used to obtain image data. The combination of Adaptive Cardio Sequence and the DSCT's maximum time resolution of 83 msec facilitates this technique in a particularly reliable fashion and permits a further significant reduction in dosage.

'The results show that CT coronary angiography with a dual-source CT in step-and-shoot mode produces images of excellent diagnostic quality in patients with stable heart rates up to 70 bpm. The dosage reduction achieved in comparison to previous CT angiography is also remarkable. In our study, we required an effective dose of 2.5 mSv on average with a deviation of plus/minus 0.8 mSv. In the literature, a normal average effective dose for heart scans of between 9 and 21 mSv is reported,' said Dr Hatem Alkadhi, specialist in Radiology at the Institute for Diagnostic Radiology, University Hospital Zurich, Switzerland.

The Adaptive Cardio Sequence supplements the step-and-shoot method with intelligent algorithms, which monitor the heart frequency of patients and, if necessary, respond to arrhythmia, such as extrasystoles, additional heart beats. In this case, the recording phase is automatically postponed in order to avoid image errors due to the sudden movement. In addition, the recording window can be widened a little more if required so that, with the Adaptive Cardio Sequence, the robustness of the CT scan can be increased significantly overall.

'For Siemens, the safety of the patients has always been the primary focus of the developments in CT. At the same time, we consider our highest obligation to be to give doctors the best diagnostic image quality and to support them in making their workflow as efficient as possible. With this outlook and constant further development, Siemens has positioned itself as the market leader in CT technology,' said Dr Sami Atiya, chief executive officer, Computed Tomography, Siemens Healthcare. 'Innovations for dose reduction in conjunction with improved diagnostic image quality, are therefore of the utmost importance to us. This is why we have also further developed our Adaptive Cardio Sequence, now for the dual-source CT. The study from Zurich confirms to us that the combination of step-and-shoot and dual-source Computed tomography does significantly reduce the dosage required during heart scans.'