Free Newsletter
Register for our Free Newsletters
Newsletter
Zones
Analysis, Inspection and Laboratory
LeftNav
Assisted/Independent Living
LeftNav
Clinical and Nursing Equipment
LeftNav
Design and Manufacture of Medical Equipment
LeftNav
Diagnostics Equipment, Monitoring and Test
LeftNav
Education, Training and Professional Services
LeftNav
Health Education and Patient Management
LeftNav
Health Estates Management
LeftNav
Healthcare Support and Information Services
LeftNav
Hygiene and Infection Control
LeftNav
IT and Communications in Healthcare
LeftNav
Materials
LeftNav
Medical Device Technology
LeftNav
Research and Development
LeftNav
Safety and Security
LeftNav
View All
Other Carouselweb publications
Carousel Web
Defense File
New Materials
Pro Health Zone
Pro Health Zone
Pro Security Zone
Web Lec
Pro Engineering Zone
 
 
News

Siemens adds intelligence features to Symbia SPECT scanner to speed results

Siemens Healthcare USA : 16 June, 2008  (New Product)
Siemens has revealed details of its newest Symbia feature, IQ- SPECT, which enables a comprehensive cardiac evaluation including perfusion, attenuation correction and calcium scoring in just five minutes.
'This exciting new Symbia feature is really all about added value and optimisation. IQ-SPECT improves the performance of the Symbia by allowing it to become organ specific and provide complete cardiac evaluations with an extremely quick turnaround time,' said Michael Reitermann, chief executive officer, Molecular Imaging, Siemens Medical Solutions USA. 'And because of its speed and versatility, IQ-SPECT offers enhanced cardiac image quality and thus offers physicians more confident diagnostic ability because of decreased patient movement. We expect this new capability to provide organ specific, cardiac imaging on general purpose systems, as it could potentially expand to other organs as well.'

IQ-SPECT technology is achieved with Smartzoom, a specially designed ‘smart’ collimator that magnifies the heart while imaging the rest of the torso under traditional conditions. Typically, cardiac SPECT data is obtained through keeping the detectors positioned at 90 degrees and as close to the body as possible, utilizing mechanically centered detector rotation, where organ specific magnification cannot be achieved.

The flexible mechanics of the Symbia S and T gantries allow an organ centric detector rotation that can zero-in on the organ of interest; in this case, the heart. Combining this organ centric orbit acquisition technique, fast, 3D iterative reconstruction that is optimised for more confident diagnoses, and improved patient comfort from a quicker scan, IQ-SPECT will set the standard for image quality, speed, productivity and throughput.

IQ-SPECT will be available for all new Symbia S and T systems, and is field upgradeable for any existing Symbia S or T systems that are already widely available in leading hospitals and imaging centers across the globe. The new Smartzoom feature is seamlessly integrated into the current Symbia workflows and automation features, giving users access to the most flexible and versatile system available today.

From a user perspective, IQ-SPECT is fully automated and can therefore accommodate more patients per day and meet a variety of patient needs. For example, paediatric patients can benefit from a lower injected dose in regular acquisition time, or from less motion and more comfort with a regular dose and quicker acquisition time. A quicker scan allows for less patient movement and lowers the probability of retakes.

Using traditional SPECT systems, cardiac perfusion studies average about 15 to 20 minutes, limiting the amount of patients per day. With an ‘intelligent’ Symbia IQ-SPECT imager, more patients can be scanned per day in much less time; as little as four minutes per patient for a full cardiac work- up.

Myocardial perfusion SPECT imaging evaluations is possible with hybrid Symbia SPECT-CT and IQ-SPECT. The addition of calcium scoring, extracted from a quick low-dose spiral CT scan that is also used to obtain attenuation correction information, is becoming a critical element in the cardiac work-up to screen patients for coronary artery disease (CAD). It can improve the risk stratification of patients who are at intermediate to high risk. Calcium scoring is an independent indicator of prognosis in CAD and in combination with SPECT, does improve diagnostic confidence.

Adding the 30-second CT to the SPECT study can not only illustrate any ischemia present in the patient, but also can assess the buildup of calcium in the coronary arteries. Because many heart attacks occur in patients without obvious signs or risk factors, calcium scoring can definitively screen for and detect CAD. The addition of IQ-SPECT to SPECT-CT studies may lead to new risk stratification algorithms and work-ups for patients with suspected CAD.